主營: 主營業務產品:隔音室,隔音房,測聽室,屏蔽室,消聲室,聲學實驗室,隔音箱,混響室,隔音門,隔音罩,流水線隔音房,沖床隔音房,同聲傳譯室等
打電話時請告知是在綠色節能環保網上看到的,謝謝!
測聽室 測聽室設計方案 目錄 1 概況···············································3 2 技術參數及說明····································3 3 設計標準及依據····································4 4 方案設計···········································4 4.1墻體隔聲設計··································4 4.2地面隔聲隔振設計······························4 4.3室內通風消音設計······························5 4.4室內吸聲內飾設計······························5 4.5隔音觀察窗的設計······························6 4.6門的隔音設計··································6 4.7室內地面環保設計·····························7 4.8 室內照明設計·································7 5 設計效果··········································7 6 聲學材料性能·····································7 6.1高強度隔聲板·································7 6.2橡膠阻尼減振墊·······························7 6.3玻璃棉········································7 7 主要材料明細·····································8 8 施工說明及驗收標準······························8 9 售后服務·········································8 10 工程預算·········································9 1 概況 本項目為醫院聽力檢測測聽室的設計方案。該測聽室對聲學設計要求非常高,符合隔振,隔聲,消聲,吸聲,安全,環保,在保證隔音量的同時最大化提升空間使用面積。 2 技術參數及說明 (1)名稱:測聽室 (2)數量:1臺 (3)規格:長X寬X高(單位:mm) 外尺寸:3200mmX2400mmX2500mm(不含通風系統) 內尺寸:2700mmX1900mmX2000mm (4)工期:自收到預付款之日起25個工作日內完成。 (5)產品說明: 結構:主體六面體,模塊結構,結構之間采用搭接口及緊鎖裝置;設計整體為雙“懸浮”結構式多層材料復合隔聲結構,具有隔聲,隔振,吸聲,換氣,防潮,安全等功能。 墻體: 雙層墻體結構,1.2mm鍍鋅鋼板噴塑,16mm防潮隔音板,復合隔聲墻體,鋼木結構,墻體厚度250mm,模塊拼裝組合式,可拆卸重裝。 減振:采用橡膠阻尼減振墊串聯方式,具有優良的隔振和耐用性能。 隔音門:雙磁控“聲閘”隔音門2套,階梯式結構。 隔音觀察窗:采用專業雙層中空隔音窗技術,透光好,隔聲性能指數高。 通風消聲系統:阻抗式復合通風消聲器,超靜音風機,強制送風導入設計,獨立進、出風口, 室內吸聲內飾:采用鋁合金沖孔鋁扣板(尺寸:600mmX600mm),使用輕鋼龍骨固定,內填充玻璃棉。 室內地面表面處理:環保隔音地毯,美觀,方便更換。 室內電源照明系統:AC220V接入,高亮LED吸頂燈,無干擾;配置照明,通風換氣開關,插座。 3 設計標準及依據 (1)《城市區域環境噪聲標準》(GB3096-93); (2)《民用建筑隔聲設計規范》(GB50118-2010); (3)《室內空氣質量標準》(GB/T18883—2002); (4)《建筑設計防火規范》(GBJ16—87)(2001年版); (5)《電氣裝置安裝工程電氣照明裝置施工及驗收規范》(GB 50259—96); (6)《民用建筑工程室內環境污染控制規范》GB50325—2010; (7)符合國標GB/T7583標準。 4 方案設計 測聽室安裝在大樓,對于此區域位置,腳步聲密集,整個樓層都有多個聲源在振動,聲能密布,而且非穩態,這就要求隔聲,消聲,減振一體化設計。 在隔聲減振工程中,減少對內噪聲的主要方式是在噪聲傳導路徑上增加阻尼構造,更重要的是處理好空氣傳聲,阻隔聲波激勵測聽室表面形成的結構聲。由于人員密集,腳步振動產生的聲音也會影響測聽室的最終隔音效果,所以本項目測聽室的結構采用“懸浮”結構式的施工方法,達到隔聲和隔振的雙重目標。 4.1墻體隔聲設計 環境聲壓級通常在峰值時會更高,為了達到測試時隔音效果,墻體采用相同的復合墻體鋼木隔聲結構,墻采用雙層16mm厚低密度高強度隔音板制造,墻體厚度為100mm,內填充50mm厚48k玻璃棉(歐文斯科寧),外表面粘貼1.2mm厚脫脂,噴塑處理的鍍鋅鋼板,雙層墻體結構,雙層墻體之間留有50mm的空腔。 測聽室內壁加裝輕鋼龍骨,沖孔鋁扣板作為內飾材料,中間填充多孔吸聲材料。 4.2 地面隔聲隔振設計 由于測聽室安裝在大樓內,且人員密集,噪聲容易使測聽室產生振動,地面受迫振動對測聽室的影響僅次于隔墻,而且低頻能力為主,底板的設計既要隔聲又要隔振。通常地面做法對高頻的阻尼效果比較好,為了應對地面的低頻振動,采取浮筑底板的做法:底板和墻體設計一樣,即復合隔聲底板;底板和樓板之間用橡膠阻尼減振墊串聯方式,能有效隔絕地板振動傳聲,具有優良的隔聲,隔振和耐用性能,雙層底板之間也采用相同的減振方式,整個底板雙重減振。 4.3 室內通風消聲設計 測聽室出于檢測時對隔聲的高要求,通常采用密閉式的設計,一般只留供采光和觀察用的隔音窗,隔音門也是隔聲密閉的;為了營造一個舒適的檢測環境,保持良好的空氣質量,測聽室的良好的通風換氣系統是必不可少的。 我公司采用阻抗式消聲器,是一個具有吸聲內忖套,迷宮式通道結構,截面為矩形的直管,吸聲元件包括多層的吸聲材料和一層透聲護面,超靜音風機,軟風管道等附件,用軟風管與消聲器上的預留進風口相連接,強制進風,進風管道密閉性能好;消聲器內部采用阻性和抗性消聲結構,既能允許氣流順利通過,達到通風換氣要求,又能有效的阻止或減弱噪聲的傳入。 測聽室安裝兩個通風消聲器,單獨進風,出風口。進風口可接空調。 4.4 室內吸聲內飾設計 為了進一步提高測聽室的隔音效果,美化室內環境,室內的內飾消聲也是不容忽視的環節,內飾材料我們采用微沖孔鋁扣板,與隔音墻體之間用輕鋼龍骨連接,扣板和墻體之間填充玻璃棉,既能有效的做到隔聲,消聲,又可以為室內提供一個環保,美觀的環境。 4.5 隔音觀察窗的設計 觀察窗我公司采用自研發的雙層中空隔音窗,是一種良好的透光,隔熱,隔音,美觀適用,并可降低測聽室自重的新型建筑材料,它是用兩片5mm隔音玻璃,使用高密度高氣密性復合粘結劑,將兩塊隔音玻璃粘結,金屬邊框固定,制成的高效能隔音隔熱玻璃。 雙層中空隔音窗隔音量高,全頻段隔音效果顯著,低頻隔音效果好;特種加工工藝,密閉性好;造型美觀,安全可靠。 4.6 門的隔音設計 本項目中的門均需要采用隔音門,我公司采用雙磁控聲閘隔音門,隔音門墻體采用1.2mm厚的國際鍍鋅鋼板,隔音門墻體外表面鋼板經過脫脂,磷化,噴塑處理(顏色客戶選擇),隔音門墻體內夾層選用阻尼板,三層50mm厚玻璃棉,高強度隔音板,隔音門結構為階梯式結構,閉合處采用雙通道磁性密封條,密閉性能好。 隔音門按照《工業企業噪聲控制標準》對隔音門設計的要求,其隔聲能力強,強度高,并且為了防止隔聲板產生振動,采取了特殊的防振處理,大大提高了隔聲效果。采用多次復合,特殊隔聲結構,密封可靠,開啟靈活。 4.7 室內地面環保設計 室內地面鋪設環保隔音地毯(400mmX400mm),美觀,經濟,方便更換和清洗。 4.8 室內照明設計 針對照明舒適問題,我公司借鑒了“間接照明”技術,燈具使用LED吸頂燈,安裝時注重光源與受光面之間的距離,與頂棚之間的距離,室內受光面也是采用的也是能夠理想反射光的裝飾面,使之在光線處理上,使之間接化,自然化,柔和華。 5 設計效果 在嚴格按照上述設計方案采取聲學處理措施后,測聽室使用時,符合國家GB/T7583標準,環境噪聲<55dB(A),測聽室室內本底噪聲≤30dB(A)的聲學要求。 6聲學材料性能 6.1高強度隔聲板 (1)厚度:16mm (2)密度:1.3g/m3 (3)熱壓溫度:195-210℃,A類,阻燃,結構均勻。 6.2橡膠阻尼減振墊 (1)厚度:20mm; (2)優點:固有頻率低,結構簡單,使用方便,壓縮變形低,許可載荷高。 6.3玻璃棉 (1)歐文斯科寧玻璃棉 (2)厚度50mm,容重16kg/m3 (3)熱導率低,保溫絕熱,吸音性能好,耐腐蝕,化學性能穩定。 7 主要材料明細表 材料名稱 規格說明 鍍鋅鋼板 1.2mm厚,脫脂,磷化,噴塑 高強度隔音板 1220*2440*16mm 阻尼控制板 現代&=3mm 玻璃棉 歐文斯科寧,50mm厚 橡膠阻尼減振墊 厚度20mm 隔音玻璃 5mm厚 磁性密封條 PV-s70/m80 照明 LED吸頂燈 電線 1.5-4mm2,二三芯 電源插座 五孔,二三插 開關 雙開 超靜音風機 綠島風 8 施工說明及驗收標準 我方施工符合JGJ73-91《建筑裝飾工程施工及驗收規范》國家標準;貴公司可派人參加質量把關,監理;為我方提供必要的施工方便。 工廠模塊化生產,現場組裝,無二次裝修痕跡。 驗收標準: 達到國家GB/T7583標準,符合環境噪聲<55 dB(A),測聽室室內本底噪聲≤30dB(A)的聲學要求。 若工程驗收不合格,我方需對測聽室進行整改至合格為止,整改費用由我方全部支付。 若需第三方檢測,出具檢測報告,檢測費用由貴公司承擔。 9 售后服務 保修期為1年,長期供應零部件,保修期內的維修費用由我司負責,易損件免費更換期1年。 保修期由設備驗收合格正常使用之日起計算,保修期內如設備出現故障,我司應接到通知后24小時內派技術人員前來維修。 質保期內如發生非人為情況下出現的破損,剝落,變形等現象或其他故障影響聲學效果或妨礙正常檢測工作的,可免費更換或維修相應的聲學部件,在超出質保期或人為損壞的情況下,按市價收取材料費或成本費用。 我公司24小時提供電話咨詢服務,在出現一般情況的小故障,在問題不算復雜或對某些技術問題存在疑問時可通過電話,傳真,EMAIL的指導方式解決問題。 保修期滿后,設備出現故障需要我司提供維修服務時,我司免費提供維修,只收取更換零部件成本費。
供應隔音房
供應電磁屏蔽
供應沖床隔音
廠家直銷隔音
供應消聲室|
供應流水線產
供應隔音室
掃一掃手機旺鋪
客戶服務熱線
86-020-82362455
給我們留言
很高興為您服務